STERIBLOC V-series
STERIBLOC V-series
Vertical flow air treatment unit
Healthcare establishments • Industries and research
Our units enable :
-
regulation and control
of air pressure
-
regulation and control
of air temperature and humidity
-
complete air treatment
of a clean room by a complex filtration system
-
Air flow from 1000 m3/h to 20000 m3/h
-
Available static pressure from 50 to 1200 Pa.
-
Three operating modes
- Fresh air + recycling,
- All fresh air
- All recycling

Download the brochure
| Nominal flow | Supply air flow range | refrigeration capacity | Heating power | Dimensions Length x Depth x Height (mm) | Weight (Kg) | |
|---|---|---|---|---|---|---|
1000 |
1100 m3/h | 700 to 1500 m3/h | 12 Kwatts | 13 Kwatts | 1430 x 630 x 1960 | 320 |
2000 |
2100 m3/h | 1500 to 2700 m3/h | 22 Kwatts | 24 Kwatts | 1430 x 840 x 1960 | 370 |
4000 |
3500 m3/h | 2700 to 4250 m3/h | 36 Kwatts | 41 Kwatts | 1560 x 970 x 1960 | 420 |
6000 |
5700 m3/h | 4250 to 7000 m3/h | 60 Kwatts | 67 Kwatts | 2020 x 970 x 1960 | 560 |
8000 |
7000 m3/h | 6500 to 8500 m3/h | 72 Kwatts | 82 Kwatts | 2020 x 970 x 1960 | 590 |
10000 |
9500 m3/h | 8000 to 10000 m3/h | 98 Kwatts | 111 Kwatts | 2820 x 970 x 1960 | 650 |
12000 |
11000 m3/h | 10000 to 14000 m3/h | 115 Kwatts | 129 Kwatts | 3030 x 970 x 1960 | 780 |
16000 |
14000 m3/h | 13000 to 17000 m3/h | 144 Kwatts | 164 Kwatts | 3870 x 970 x 1960 | 1010 |
24000 |
22000 m3/h | 16000 to 28000 m3/h | 230 Kwatts | 258 Kwatts | 5470 x 970 x 1960 | 1370 |
Calculation basis for air handling units :
Nominal air flow rate – 100% fresh air – Summer fresh air: 32°C – 40% – Cooling coil outlet: 11°C – 99% – Winter fresh air: -7°C – 90% – Heating coil outlet: 28°C
Dimensions and weight:
The width corresponds to the treatment module with a small electrical module (add 210 mm with a large electrical module); the weight indications are averages based on different selections
The characteristics indicated in this table are given for information only and may vary according to customer demand.
COMPLIANT WITH STANDARDS: EN 1886 / NF S 90-351 / EN 13053 +A1 / BPF / ISO 14644
-
ALUMINUM PROFILE frame, with rupture of the THERMAL BRIDGE
-
Double skin paneling with cast joints,
exterior in painted sheet steel and tstainless steel inner sheet with compression closure.
-
Very advanced thermal and sound insulation,
panel thickness 42mm with stone wool insulation of 90kg/m3 density guaranteeing the absence of external condensation and excellent acoustic comfort. Fire classification A1 – incombustible EN 13 501 -1
-
Centrifugal fan, EC motor with external rotor direct coupling,
ensuring high efficiency and no pollution due to belt wear.
-
Constant air flow control based on filter clogging
-
Switching duration between cold exchanger or evaporator 2,5 m/s top
-
Stainless steel condensate and water collection pan (consistent with the recommendations of the standard NF S 90-351) April 2013
-
Static pressures available from 50 to 1200 Pa
to combat pressure losses from air networks and from absolute filtration units.
-
Three operating modes:
fresh air + recirculated air, all fresh air or all recirculated air.
-
Adjustment of fresh or extract air flow rates
to obtain the desired pressure level in the premises
-
Advanced air filtration,
Three-stage, adapted to the required dust class
-
Precise integrated temperature regulation whatever the external conditions:
• Cooling mode: the cooling capacity is provided by a direct expansion condensing unit or by a chilled water network • Heating mode: the heating capacity is provided by electric heaters or by a hot water network
-
Efficient regulation of relative humidity:
• Dehumidification by condensation on the cooling coil • Humidification by steam generator (optional)