STERIBLOC H-series

STERIBLOC H​-series

Horizontal flow air treatment unit

Healthcare establishments • Industries and research

External version
Inside version
  • Air flow from 1000 m3/h to 20000 m3/h

  • Available static pressure from 50 to 1200 Pa.

  • Three operating modes

    • Fresh air + recycling,
    • All fresh air
    • All recycling

Download the brochure

Nominal flowAir flow rangeCooling capacityHeating capacitySizesWidth x Length x Height (mm)Weight (Kg)
1000
1100 m3/h700 to 1800 m3/h12 Kwatts13 Kwatts2490 x 840 x 730320
2000
2100 m3/h1500 to 2700 m3/h22 Kwatts24 Kwatts2490 x 840 x 940370
4000
3500 m3/h2700 to 4250 m3/h36 Kwatts41 Kwatts2490 x 970 x 1070420
6000
5700 m3/h4250 to 7000 m3/h60 Kwatts67 Kwatts2490 x 1430 x 1070560
8000
7000 m3/h5500 to 8500 m3/h72 Kwatts82 Kwatts2490 x 1640 x 1070590
10000
9500 m3/h8000 to 10800 m3/h98 Kwatts111 Kwatts2490 x 1960 x 1070650
12000
11000 m3/h10000 to 13000 m3/h114 Kwatts129 Kwatts2490 x 1430 x 1740780
16000
14000 m3/h12000 to 16000 m3/h145 Kwatts164 Kwatts2490 x 1640 x 17401010
20000
19000 m3/h16000 to 20000 m3/h196 Kwatts223 Kwatts2490 x 1960 x 17401370

Calculation basis for air treatment units:
Nominal air flow – 100 % fresh air – Fresh air summer : 32°C – 40% – Cold battery output : 11°C – 99% – Fresh air winter : -7°C – 90% – Hot battery output : 28°C

Dimensions :
NB : With a preheating battery, 340 mm must be added to the length of 2490 mm

The characteristics indicated in this table are given for information only and may vary according to customer demand.

THE FEATURES THAT MAKE THE DIFFERENCE
COMPLIANT WITH STANDARDS REQUIREMENTS : EN 1886 / NF S 90-351 / EN 13053 +A1 / BPF / ISO 14644
  • Aluminum profile frame with thermal break

  • Double-skin paneling with injected gaskets,

    exterior in painted sheet steel and interior sheet in stainless steel with compression latching.

  • Highly advanced thermal and acoustic insulation,

    panel thickness 42 mm with rock wool insulation at a density of 90 kg/m³, ensuring no external condensation and excellent acoustic comfort. Fire classification A1 – non-combustible according to EN 13501‑1.

  • Centrifugal fan with EC motor and external rotor, direct-coupled,

    ensuring high efficiency and no contamination from belt wear.

  • Constant airflow control based on filter clogging.

  • Air velocity over the heat exchanger or cold evaporator: maximum 2.5 m/s.

  • Condensate tray and water collector in stainless steel (compliant with the recommendations of standard NF S 90‑351, April 2013).

  • Static pressures available from 50 to 1200 Pa

    to fight pressure losses in air distribution networks and absolute filtration units

  • Three operating modes:

    fresh air + recirculation, 100% fresh air, or 100% recirculation.

  • Adjustment of fresh air or exhaust airflow rates

    to obtain the desired pressure level in the rooms

  • Advanced air filtration,

    with three stages, adapted to the required dust classification

  • Precise integrated temperature control, regardless of outdoor conditions:

    Cooling mode: the cooling capacity is provided by a direct expansion condensing unit or by a chilled water network • Heating mode: the heating capacity is provided by electric heaters or by a hot water network

  • Effective control of relative humidity:

    • Dehumidification by condensation on a cooling coil • Humidification by steam generator (optional)